Home / Engineering Center

Engineering Resources for 1535nm Laser Sources

Datasheets, mechanical drawings, integration notes and terminology, organised so a design engineer can reach the numbers without a sales conversation.

Documents by Model

Every model in the range publishes a specification datasheet and a 3D model, both linked directly below. The 3D files are glTF binary and open in any viewer or CAD tool; the STEP source is available on request through the contact page.

Reading these documents

  • Specification values are published as minima at the stated drive and temperature conditions. Confirm them against the factory test report supplied with the unit.
  • Dimensioned drawings and the controlled STEP source are released on request, with your project context, so the correct revision is issued.
  • Where two models share a mechanical and environmental table, that is stated on the datasheet itself; optical specifications are always per model.

From Application to Controlled Design

A rangefinder is not defined by pulse energy or nominal distance alone. Stable field behaviour depends on how the gain medium, resonator, coatings, transmitter, receiver, timing electronics, mechanics and firmware are designed and verified together.

  1. Application definition
    Target, atmosphere, range, update rate, host optics and acceptance criteria.
  2. Optical link budget
    Transmitter, beam, target return, aperture, detector and noise margin.
  3. Electronics and firmware
    Power, timing, receiver chain, mode logic, interface and fault behaviour.
  4. Optomechanical packaging
    Datums, boresight, thermal path, connector, window and service envelope.
  5. Prototype verification
    Measured behaviour compared with the controlled model specification.
  6. Design transfer and revision
    Build controls, test instructions, release record and managed updates.

Terminology and Conditions

How the numbers on a product page should be read.

  • Pulse energy
    Energy per pulse, stated as a minimum at the specified drive and temperature conditions.
  • Pulse width
    Optical pulse duration (FWHM) unless stated otherwise.
  • Drive pulse width
    Electrical drive duration, distinct from the optical pulse.
  • Beam divergence
    Full angle unless stated otherwise.
  • Raw beam diameter
    Beam diameter at the package output, before host optics.
  • Repetition rate
    Adjustable range; the nominal operating point may differ and is stated where applicable.
  • Directivity
    Angular alignment of the emitted beam relative to the package datum.

Technical FAQ

  • Are values guaranteed or typical?
    Confirm against the factory test report supplied with the unit.
  • Can I request a drawing?
    Yes — request through Contact / RFQ with your project context.
  • Do you supply STEP models?
    Yes, per model, for mechanical integration.
  • Why do some models share a datasheet?
    The high-repetition family (ER10–ER70) is published as one document because its optical parameters vary by model while its mechanical and environmental values are common to the family.
  • Which values are family-wide rather than per-model?
    On high-repetition pages the mechanical and environmental table is labelled as shared. Optical specifications are per model.

Before you specify

Confirm operating temperature range, drive conditions and the host interface against the model datasheet. The exact inspection plan is model- and order-specific.

ERDI LASER

1535nm Laser Technology

What is a 1535 nm Laser?A 1535 nm laser is a pulsed solid-state laser that emits in the 1.5 µm eye-safe band. The wavelength sits at the boundary of the retinal hazard region: 1535 nm light is strongly absorbed by the cornea and the lens before it can reach the retina, so the permissible exposure limit is orders of magnitude higher than at 905 nm. That is why 1535 nm sources can be operated at higher pulse energy in open environments — the property that makes long-range, eye-safe ranging and LiDAR practical.ERDI builds 1535 nm sources on Er:Yb glass (erbium–ytterbium co-doped phosphate glass), pumped by a 940–980 nm laser diode, in a microchip resonator that is Q-switched to produce 3.5–13 ns pulses from 10 µJ to 10 mJ.1535 nm laser — the emission wavelength of the Er:Yb glass gain mediumEye-safe laser — the 1.5 µm band, where corneal absorption protects the retina1.5 µm laser — the same band, referenced by wavelength rather than by nanometresWhy choose 1535 nm over 905 nm?Most short-range LiDAR and rangefinder designs start at 905 nm because silicon detectors are cheap and sensitive there. The trade appears as soon as the system has to reach further, or operate where people are present.Parameter1535 nm905 nmEye safetyExcellent — energy is absorbed by the cornea before reaching the retina; much higher permissible exposure at the same pulse energyLimited — energy focuses onto the retina; permissible exposure is far lowerAtmospheric lossLow — outside the strong water-vapour absorption lines, good transmission in haze and light fogHigher — more scattering in haze, fog and precipitationRange capabilityLonger — higher usable pulse energy at the same eye-safety classMedium — energy is capped by eye-safety limitsSystem sizeCompact — microchip source from 14.5 × 6.3 × 4.37 mm / 2.5 gCompact — comparable emitter sizeDetectorInGaAs (or upconversion / SiGe APD)Silicon APDTypical useLong-range ranging, UAV LiDAR, mobile mapping, remote sensingShort-range LiDAR, proximity sensing, consumer ToFNeither wavelength is universally better. 905 nm wins on detector cost and availability; 1535 nm wins wherever range, atmospheric margin or eye safety in populated areas decide the specification.ERDI technology: 1535 nm Er:Yb glass microchip lasersOur sources are built as a single passive assembly rather than a free-space bench, which is what makes the 2.5 g packages possible.ElementWhat it doesEr:Yb glassErbium–ytterbium co-doped phosphate glass. Ytterbium absorbs the 940–980 nm pump band efficiently and transfers the energy to erbium, which lases at 1535 nm. The glass host allows very high doping in a few millimetres of material.Microchip structureGain medium, saturable absorber and cavity mirrors are bonded into one monolithic chip. No alignment, no adjustable optics, and the cavity length is set by the chip thickness — which fixes the pulse width in the few-nanosecond range.LD pumpingA 940–980 nm laser diode pumps the chip through its face. Drive conditions stay simple and low-voltage: 2 V for the compact range, ≤ 14 V for the multi-mJ models, with drive pulse widths from ≤ 1.1 ms.Q-switched operationPassive Q-switching by the bonded saturable absorber produces short, high-peak-power pulses without an external driver or high-voltage switching stage — energy from 10 µJ to 10 mJ in 3.5–13 ns.The result is a source with no warm-up, no alignment drift, TEM00 output, 0.3–0.8 mm raw beam diameter and stable operation from −40 °C to +65 °C — specified for integration rather than for a laboratory bench.Where 1535 nm sources are usedLaser ranging — handheld, vehicle and gimbal rangefinders from 100 µJ to 10 mJUAV LiDAR — SWaP-critical transmitters from 2.5 gMobile mapping — 800 µJ to 2 mJ at 1–10 Hz for corridor-scale coverageRemote sensing and research — up to 10 mJ for extended link budget and experimental transmittersSee Applications for the parameter sets these systems need, and OEM Solutions for integration and customisation.Frequently askedIs 1535 nm really eye-safe?It is eye-safe in the sense that the eye-safety limit is far higher than at visible or 905 nm wavelengths: the cornea absorbs 1.5 µm radiation before it reaches the retina. It is not "safe at any power" — the source still has to be classified and the system still has to be evaluated against the applicable laser safety standard.What pulse energy do I need?Enough to close your link budget, with margin. A practical starting point: 10–100 µJ for short-range handheld and dense industrial sensing, 200–500 µJ for multi-kilometre ranging and long-range LiDAR, 0.8–2 mJ for mobile mapping and extended observation, 4–10 mJ for remote sensing and ultra-long-range channels.Why is the pulse width fixed?Because it is set by the microchip cavity, not by an external driver. The short pulse concentrates the energy in time, which raises peak power and improves the signal the receiver sees for a given pulse energy.-Laser Ranging Total Solution - ERDI

What is a 1535 nm Laser?

A 1535 nm laser is a pulsed solid-state laser that emits in the 1.5 µm eye-safe band. The wavelength sits at the boundary of the retinal hazard region: 1535 nm light is strongly absorbed by the cornea and the lens before it can reach the retina, so the permissible exposure limit is orders of magnitude higher than at 905 nm. That is why 1535 nm sources can be operated at higher pulse energy in open environments — the property that makes long-range, eye-safe ranging and LiDAR practical.

ERDI builds 1535 nm sources on Er:Yb glass (erbium–ytterbium co-doped phosphate glass), pumped by a 940–980 nm laser diode, in a microchip resonator that is Q-switched to produce 3.5–13 ns pulses from 10 µJ to 10 mJ.

  • 1535 nm laser — the emission wavelength of the Er:Yb glass gain medium
  • Eye-safe laser — the 1.5 µm band, where corneal absorption protects the retina
  • 1.5 µm laser — the same band, referenced by wavelength rather than by nanometres

Why choose 1535 nm over 905 nm?

Most short-range LiDAR and rangefinder designs start at 905 nm because silicon detectors are cheap and sensitive there. The trade appears as soon as the system has to reach further, or operate where people are present.

Parameter1535 nm905 nm
Eye safetyExcellent — energy is absorbed by the cornea before reaching the retina; much higher permissible exposure at the same pulse energyLimited — energy focuses onto the retina; permissible exposure is far lower
Atmospheric lossLow — outside the strong water-vapour absorption lines, good transmission in haze and light fogHigher — more scattering in haze, fog and precipitation
Range capabilityLonger — higher usable pulse energy at the same eye-safety classMedium — energy is capped by eye-safety limits
System sizeCompact — microchip source from 14.5 × 6.3 × 4.37 mm / 2.5 gCompact — comparable emitter size
DetectorInGaAs (or upconversion / SiGe APD)Silicon APD
Typical useLong-range ranging, UAV LiDAR, mobile mapping, remote sensingShort-range LiDAR, proximity sensing, consumer ToF

Neither wavelength is universally better. 905 nm wins on detector cost and availability; 1535 nm wins wherever range, atmospheric margin or eye safety in populated areas decide the specification.

ERDI technology: 1535 nm Er:Yb glass microchip lasers

Our sources are built as a single passive assembly rather than a free-space bench, which is what makes the 2.5 g packages possible.

ElementWhat it does
Er:Yb glassErbium–ytterbium co-doped phosphate glass. Ytterbium absorbs the 940–980 nm pump band efficiently and transfers the energy to erbium, which lases at 1535 nm. The glass host allows very high doping in a few millimetres of material.
Microchip structureGain medium, saturable absorber and cavity mirrors are bonded into one monolithic chip. No alignment, no adjustable optics, and the cavity length is set by the chip thickness — which fixes the pulse width in the few-nanosecond range.
LD pumpingA 940–980 nm laser diode pumps the chip through its face. Drive conditions stay simple and low-voltage: 2 V for the compact range, ≤ 14 V for the multi-mJ models, with drive pulse widths from ≤ 1.1 ms.
Q-switched operationPassive Q-switching by the bonded saturable absorber produces short, high-peak-power pulses without an external driver or high-voltage switching stage — energy from 10 µJ to 10 mJ in 3.5–13 ns.

The result is a source with no warm-up, no alignment drift, TEM00 output, 0.3–0.8 mm raw beam diameter and stable operation from −40 °C to +65 °C — specified for integration rather than for a laboratory bench.

Where 1535 nm sources are used

  • Laser ranging — handheld, vehicle and gimbal rangefinders from 100 µJ to 10 mJ
  • UAV LiDAR — SWaP-critical transmitters from 2.5 g
  • Mobile mapping — 800 µJ to 2 mJ at 1–10 Hz for corridor-scale coverage
  • Remote sensing and research — up to 10 mJ for extended link budget and experimental transmitters

See Applications for the parameter sets these systems need, and OEM Solutions for integration and customisation.

Frequently asked

Is 1535 nm really eye-safe?

It is eye-safe in the sense that the eye-safety limit is far higher than at visible or 905 nm wavelengths: the cornea absorbs 1.5 µm radiation before it reaches the retina. It is not "safe at any power" — the source still has to be classified and the system still has to be evaluated against the applicable laser safety standard.

What pulse energy do I need?

Enough to close your link budget, with margin. A practical starting point: 10–100 µJ for short-range handheld and dense industrial sensing, 200–500 µJ for multi-kilometre ranging and long-range LiDAR, 0.8–2 mJ for mobile mapping and extended observation, 4–10 mJ for remote sensing and ultra-long-range channels.

Why is the pulse width fixed?

Because it is set by the microchip cavity, not by an external driver. The short pulse concentrates the energy in time, which raises peak power and improves the signal the receiver sees for a given pulse energy.

Laser source assembly and test, Chengdu.
Laser source assembly and test, Chengdu.