Driving an Er:Yb Glass Source: Current, Pulse Width and Ground Return | ERDI

Oct 21, 2026 Yilin

Driving an Er:Yb Glass Source: Current, Pulse Width and Ground Return

The pump diode decides how much energy ends up in the glass. The driver decides whether the diode ever gets what it was rated for.

Most integration problems with these sources are electrical. The diode is rated 2 V and 20 A, the bench supply is rated 2 V and 20 A, and the laser still under-performs — because the 20 A never arrives at the diode terminal at the moment it matters.

The current is the hard part

Peak current runs from 5 A on the high-repetition models to 100 A on the millijoule transmitters. Voltage does not scale with it: ER10 through ER900 all run from 2 V. Only the ER2000 and ER4000 move to 5 V, and the ER8000 and ER10000 to 14 V.

So the constraint is rarely the rail's steady-state rating. It is whether the rail holds voltage during the pulse. A bench meter shows the average and looks healthy while the pulse sags. Measure at the module, with a scope.

Pulse width is a ceiling, not a setting

ER100 to ER500 allow 2.4 ms. ER800 and ER900, 3 ms. ER2000 and larger, 4 ms. The high-repetition family stops at 0.3–0.4 ms.

Going past it buys heat, not output. The coating sees more fluence than it was qualified for, and the gain medium spends longer recovering. Tune the driver for output and you will usually be trading life for a few percent.

Charge per shot explains the driver topology

Take the ER500: 20 A for up to 2.4 ms is 48 mC per shot. At 10 Hz that averages 0.48 A — a twentieth of the peak.

That ratio rules out the obvious circuit. A capacitor bank holding 0.2 V of droop through 48 mC needs about 240 mF. Practical drivers are switching converters with an inductor and a current loop; the supply sees the average, and the driver holds the pulse.

Ground return

The receiver in a rangefinder works in microvolts. A 20 A pulse returning through shared copper is a false echo. Give the laser its own return, join it to signal ground at one point, keep the loop small, and route the trigger away from it.

Trigger and timestamps

Trigger-to-optical delay is fixed per unit within a tolerance. Jitter is not. If the host gates a receiver or fuses range with imagery, measure both once and treat the delay as a constant.

Do not timestamp when the serial result arrives. That measures the link, not the pulse.

Bench checks

  • Supply voltage at the module during the pulse
  • Drive pulse within the published ceiling
  • Bulk capacitance at the driver input, not only at the supply
  • Single join point between laser return and signal ground
  • Inhibit, soft start and thermal interlock wired and tested

When one of these is wrong, it is usually the first.