{% comment %} ERDI page renderer — the single template behind every CMS page. Why this exists --------------- Six live pages (/pages/applications, /pages/oem-solutions, /pages/1535nm-laser-technology, /pages/privacy-policy, /pages/tracking, /pages/html-sitemap) held 4,000-11,000 characters of real content each in the page editor, but the template that rendered them output a leftover diagnostic block instead. Visitors saw the literal text "PROBE {% schema %}" and none of the content. Measured before writing this (see tools/probe-template-branching.mjs, tools/probe-page-fields.mjs): applications renders -> used to select page-specific extras Applications renders -> used as the H1

1535 nm Eye-Safe Laser Sources for Ranging, LiDAR and Mapping Systems

ERDI builds 1535 nm Er:Yb glass microchip laser sources for four application families: UAV LiDAR, laser rangefinding, mobile mapping and robotics / industrial sensing. Pulse energy runs from 10 µJ to 10 mJ in the same wavelength and the same microchip format, so a single optical and receiver concept can be scaled across a product line. Typical pulse width is 3.5–13 ns, repetition rate 1–10 Hz, raw beam diameter 0.3–0.8 mm, and operating temperature −40 °C to +65 °C.

Every figure below is taken from the published datasheet of the model named. If your requirement is outside these ranges, the OEM Solutions page describes how we adapt the source, the beam and the drive interface.

Applications at a glance

Application What drives the choice Recommended models Pulse energy
UAV LiDAR Payload mass, power budget, eye safety MINI-100, ER400, ER500 100–500 µJ
Laser rangefinding Target range, receiver sensitivity, envelope ER500, ER2000, ER4000, ER10000 0.5–10 mJ
Mobile mapping Repetition rate, pulse stability, point density ER800, ER900, ER2000 0.8–2 mJ
Robotics & industrial Repetition rate, drive voltage, service life MINI-100, ER100, ER200 100–200 µJ

UAV LiDAR

What matters on an aircraft: mass and power budget, eye safety over the operating area, and a beam that survives vibration and temperature swing. Our compact sources are built for exactly that trade: the MINI-100 weighs 2.5 g in a 14.5 × 6.3 × 4.37 mm package at 100 µJ, and the ER400 reaches 400 µJ at 12 g with 30 A drive from 2 V. The compact models are qualified to MIL-STD-810G shock (1500 G, 0.5 ms) and vibration (20–2000 Hz / 20 G) methods.

Recommended model Pulse energy / width Rep. rate Package / mass Drive
MINI-100 100 µJ / 3.5 ns 1–10 Hz 14.5 × 6.3 × 4.37 mm / 2.5 g 2 V / 12 A
ER400 400 µJ / 6 ns 10 Hz 35 × 8 × 6.8 mm / 12 g 2 V / 15 A
ER500 500 µJ / 6 ns 1–10 Hz 35 × 8 × 6.8 mm / 12 g 2 V / 20 A

System notes. 1535 nm sits far above the 905 nm eye-safety limit in permitted exposure, which matters when the aircraft flies over people or roads. TEM00 output and 0.3 mm raw beam diameter let your collimator set divergence and footprint; the source does not impose a fixed beam. Drive pulse width is ≤ 1.1 ms on MINI-100 and ≤ 2.4 ms on ER400 / ER500, so the trigger can come from the same timing board that fires the scanner.

Laser rangefinding

What matters in a rangefinder: pulse energy against target range, pulse stability against the receiver threshold, and a package that fits the housing you have already tooled. Every model shares the same 1535 nm wavelength, so one receiver and one signal-processing chain can serve several product tiers — from a handheld to a long-range observation unit.

Typical tier Recommended model Pulse energy / width Package / mass Pulse stability
Handheld, short range MINI-100 / ER100 100 µJ / 3.5–6 ns 14.5–21 mm / 2.5–7 g 10 %
Handheld, medium range ER500 500 µJ / 6 ns 35 × 8 × 6.8 mm / 12 g 10 %
Long-range observation ER2000 / ER4000 2–4 mJ / 12 ns 60 × 25 × 13.5 mm / 105 g 10 %
Extended range, low rep-rate ER8000 / ER10000 8–10 mJ / 12–13 ns 110 × 40 × 24.5 mm / 220 g 5 %

Range scaling. Detected range is set by the link budget, not by the laser alone: pulse energy, beam divergence, target reflectivity, atmospheric transmission and receiver sensitivity / aperture all enter it. The practical way to work with us is to state the target range and target type, and let our engineering team match the source and the drive conditions to your receiver. A 4× increase in pulse energy does not give a 4× increase in range — it gives roughly 2× in the ideal case, before atmospheric and target effects.

Mobile mapping

What matters on a mapping platform: enough pulses per second to reach the point spacing your specification calls for, pulse-to-pulse stability that keeps intensity returns comparable, and a source that behaves the same at −40 °C as it does at +65 °C. Mobile mapping favours the high-energy tier at the top of the standard 1–10 Hz repetition band, because the vehicle or backpack carries more mass and power than a small UAV.

Recommended model Pulse energy / width Rep. rate Raw beam Package / mass
ER800 800 µJ / 7 ns 1–10 Hz 0.3 mm 40 × 8 × 7.5 mm / 18 g
ER900 900 µJ / 7 ns 1–5 Hz 0.3 mm 40 × 8 × 7.5 mm / 18 g
ER2000 2 mJ / 12 ns 1–10 Hz 0.5 mm 60 × 25 × 13.5 mm / 105 g

Mapping notes. Point density comes from repetition rate combined with platform speed and scan pattern; when the platform moves fast, the 10 Hz end of the band is the one that keeps ground sampling distance within specification. Pulse stability of 5–10 % keeps return amplitude comparable across a corridor strip, which simplifies intensity calibration in post-processing. Storage temperature is −55 °C on the full family, so field logistics between deployments do not need special handling.

Robotics & industrial sensing

What matters in an industrial product: repetition rate first, then drive simplicity, then service life. Robotics and industrial sensors run continuously rather than in measurement bursts, so the compact, high-repetition models are the right starting point: 10 Hz at 100–200 µJ, 2 V drive, and a package a few centimetres long that can be integrated next to the scanning mechanism.

Recommended model Pulse energy / width Rep. rate Package / mass Drive
MINI-100 100 µJ / 3.5 ns 1–10 Hz 14.5 × 6.3 × 4.37 mm / 2.5 g 2 V / 12 A
ER100 100 µJ / 6 ns 1–10 Hz 21 × 8 × 6.8 mm / 7 g 2 V / 8 A
ER200 200 µJ / 5 ns 10 Hz 21 × 8 × 6.8 mm / 7 g 2 V / 10 A

Integration notes. A 2 V drive rail is available on the whole compact tier, which keeps the driver stage small and low-cost. Service life is specified as ≥ 1 million shots on the compact models — we quote the datasheet figure, not a marketing multiple. For duty cycles that exceed the published repetition rate, talk to us before designing the thermal path: the limit is in the drive and thermal design, and that is a conversation worth having at concept stage.

Choosing pulse energy for your range

If your system needs Start from Pulse energy
Short-range handheld, dense industrial sensing Compact family (10–100 µJ) 10–100 µJ
Multi-kilometre ranging, long-range LiDAR Standard family (200–500 µJ) 200–500 µJ
Mobile mapping, extended observation High-energy family (0.8–2 mJ) 0.8–2 mJ
Remote sensing, ultra-long-range channels Ultra-high-energy family (4–10 mJ) 4–10 mJ

What to send with an application enquiry

Send these to our engineering team through the contact page, or see OEM Solutions if your requirement needs a custom beam, interface or mechanical adaptation.

renders -> the manager-editable body, rendered as HTML So the content stays editable in the SHOPLINE page editor and this template supplies the frame. {% endcomment %}

Applications

Home Applications

1535 nm Eye-Safe Laser Sources for Ranging, LiDAR and Mapping Systems

ERDI builds 1535 nm Er:Yb glass microchip laser sources for four application families: UAV LiDAR, laser rangefinding, mobile mapping and robotics / industrial sensing. Pulse energy runs from 10 µJ to 10 mJ in the same wavelength and the same microchip format, so a single optical and receiver concept can be scaled across a product line. Typical pulse width is 3.5–13 ns, repetition rate 1–10 Hz, raw beam diameter 0.3–0.8 mm, and operating temperature −40 °C to +65 °C.

Every figure below is taken from the published datasheet of the model named. If your requirement is outside these ranges, the OEM Solutions page describes how we adapt the source, the beam and the drive interface.

Applications at a glance

Application What drives the choice Recommended models Pulse energy
UAV LiDAR Payload mass, power budget, eye safety MINI-100, ER400, ER500 100–500 µJ
Laser rangefinding Target range, receiver sensitivity, envelope ER500, ER2000, ER4000, ER10000 0.5–10 mJ
Mobile mapping Repetition rate, pulse stability, point density ER800, ER900, ER2000 0.8–2 mJ
Robotics & industrial Repetition rate, drive voltage, service life MINI-100, ER100, ER200 100–200 µJ

UAV LiDAR

What matters on an aircraft: mass and power budget, eye safety over the operating area, and a beam that survives vibration and temperature swing. Our compact sources are built for exactly that trade: the MINI-100 weighs 2.5 g in a 14.5 × 6.3 × 4.37 mm package at 100 µJ, and the ER400 reaches 400 µJ at 12 g with 30 A drive from 2 V. The compact models are qualified to MIL-STD-810G shock (1500 G, 0.5 ms) and vibration (20–2000 Hz / 20 G) methods.

Recommended model Pulse energy / width Rep. rate Package / mass Drive
MINI-100 100 µJ / 3.5 ns 1–10 Hz 14.5 × 6.3 × 4.37 mm / 2.5 g 2 V / 12 A
ER400 400 µJ / 6 ns 10 Hz 35 × 8 × 6.8 mm / 12 g 2 V / 15 A
ER500 500 µJ / 6 ns 1–10 Hz 35 × 8 × 6.8 mm / 12 g 2 V / 20 A

System notes. 1535 nm sits far above the 905 nm eye-safety limit in permitted exposure, which matters when the aircraft flies over people or roads. TEM00 output and 0.3 mm raw beam diameter let your collimator set divergence and footprint; the source does not impose a fixed beam. Drive pulse width is ≤ 1.1 ms on MINI-100 and ≤ 2.4 ms on ER400 / ER500, so the trigger can come from the same timing board that fires the scanner.

Laser rangefinding

What matters in a rangefinder: pulse energy against target range, pulse stability against the receiver threshold, and a package that fits the housing you have already tooled. Every model shares the same 1535 nm wavelength, so one receiver and one signal-processing chain can serve several product tiers — from a handheld to a long-range observation unit.

Typical tier Recommended model Pulse energy / width Package / mass Pulse stability
Handheld, short range MINI-100 / ER100 100 µJ / 3.5–6 ns 14.5–21 mm / 2.5–7 g 10 %
Handheld, medium range ER500 500 µJ / 6 ns 35 × 8 × 6.8 mm / 12 g 10 %
Long-range observation ER2000 / ER4000 2–4 mJ / 12 ns 60 × 25 × 13.5 mm / 105 g 10 %
Extended range, low rep-rate ER8000 / ER10000 8–10 mJ / 12–13 ns 110 × 40 × 24.5 mm / 220 g 5 %

Range scaling. Detected range is set by the link budget, not by the laser alone: pulse energy, beam divergence, target reflectivity, atmospheric transmission and receiver sensitivity / aperture all enter it. The practical way to work with us is to state the target range and target type, and let our engineering team match the source and the drive conditions to your receiver. A 4× increase in pulse energy does not give a 4× increase in range — it gives roughly 2× in the ideal case, before atmospheric and target effects.

Mobile mapping

What matters on a mapping platform: enough pulses per second to reach the point spacing your specification calls for, pulse-to-pulse stability that keeps intensity returns comparable, and a source that behaves the same at −40 °C as it does at +65 °C. Mobile mapping favours the high-energy tier at the top of the standard 1–10 Hz repetition band, because the vehicle or backpack carries more mass and power than a small UAV.

Recommended model Pulse energy / width Rep. rate Raw beam Package / mass
ER800 800 µJ / 7 ns 1–10 Hz 0.3 mm 40 × 8 × 7.5 mm / 18 g
ER900 900 µJ / 7 ns 1–5 Hz 0.3 mm 40 × 8 × 7.5 mm / 18 g
ER2000 2 mJ / 12 ns 1–10 Hz 0.5 mm 60 × 25 × 13.5 mm / 105 g

Mapping notes. Point density comes from repetition rate combined with platform speed and scan pattern; when the platform moves fast, the 10 Hz end of the band is the one that keeps ground sampling distance within specification. Pulse stability of 5–10 % keeps return amplitude comparable across a corridor strip, which simplifies intensity calibration in post-processing. Storage temperature is −55 °C on the full family, so field logistics between deployments do not need special handling.

Robotics & industrial sensing

What matters in an industrial product: repetition rate first, then drive simplicity, then service life. Robotics and industrial sensors run continuously rather than in measurement bursts, so the compact, high-repetition models are the right starting point: 10 Hz at 100–200 µJ, 2 V drive, and a package a few centimetres long that can be integrated next to the scanning mechanism.

Recommended model Pulse energy / width Rep. rate Package / mass Drive
MINI-100 100 µJ / 3.5 ns 1–10 Hz 14.5 × 6.3 × 4.37 mm / 2.5 g 2 V / 12 A
ER100 100 µJ / 6 ns 1–10 Hz 21 × 8 × 6.8 mm / 7 g 2 V / 8 A
ER200 200 µJ / 5 ns 10 Hz 21 × 8 × 6.8 mm / 7 g 2 V / 10 A

Integration notes. A 2 V drive rail is available on the whole compact tier, which keeps the driver stage small and low-cost. Service life is specified as ≥ 1 million shots on the compact models — we quote the datasheet figure, not a marketing multiple. For duty cycles that exceed the published repetition rate, talk to us before designing the thermal path: the limit is in the drive and thermal design, and that is a conversation worth having at concept stage.

Choosing pulse energy for your range

If your system needs Start from Pulse energy
Short-range handheld, dense industrial sensing Compact family (10–100 µJ) 10–100 µJ
Multi-kilometre ranging, long-range LiDAR Standard family (200–500 µJ) 200–500 µJ
Mobile mapping, extended observation High-energy family (0.8–2 mJ) 0.8–2 mJ
Remote sensing, ultra-long-range channels Ultra-high-energy family (4–10 mJ) 4–10 mJ

What to send with an application enquiry

  • Application type (UAV LiDAR / rangefinding / mobile mapping / robotics & industrial)
  • Target range and target type (reflectivity, size)
  • Receiver: detector type, aperture, sensitivity
  • Required pulse energy, pulse width and repetition rate
  • Beam diameter and divergence you need at exit
  • Available drive voltage and trigger interface
  • Package envelope, mass limit and operating environment
  • Prototype quantity and annual volume

Send these to our engineering team through the contact page, or see OEM Solutions if your requirement needs a custom beam, interface or mechanical adaptation.

Discuss Your Application Requirements

Tell us about your system, target parameters and integration constraints. Our team will review the information and advise on the most appropriate next step.