Reading a Laser Datasheet: Guaranteed vs Typical | ERDI

2026年10月15日 Erdicn

Reading a Laser Datasheet: Which Values Are Guaranteed

*A specification table looks like a list of facts. In practice it mixes guaranteed minima, typical figures and

test conditions, and treating all three the same is how a design ends up not meeting its requirement. This

article explains how to read each kind of value in the ERDI datasheets — and, where a value varies across the

range, why.*

In short: a value preceded by ≥ or ≤ is a limit the part is accepted against. A value with no symbol is

either a nominal operating point or a property of the design. Environmental figures are demonstrated by test,

not by inspection of every unit. Ask which one you are reading before you design to it.


Why the distinction matters

A datasheet has to serve several readers at once: the engineer checking whether a part will work, the purchasing

team comparing options, and the quality function defining what will be accepted. The table is compressed to do

all three jobs.

That compression hides information. Three different kinds of statement appear in the same column:

A guaranteed limit — every unit is accepted against it. If the datasheet says pulse energy is ≥800 µJ, a

unit that delivers 750 µJ does not ship.

A nominal value — what a typical unit does, useful for design but not a commitment per unit.

A design property — a quantity that follows from the construction, such as the wavelength or the beam

quality. It is not measured on every unit because it cannot meaningfully vary.

Designing to a nominal as though it were a limit is the common error. The part will work on the bench and fail

at the acceptance test.


The symbols, and what they mean here

Every model in this range publishes its specification in the same form. The symbols are consistent and worth

knowing:

Symbol Meaning How to treat it
≥ At least this value A guaranteed minimum. Design to it, not above it
≤ At most this value A guaranteed maximum. This is a limit to respect
No symbol Nominal or design property Confirm against the test report before relying on it
Ranges (1–10 Hz) Adjustable range The nominal operating point within it may differ

Applied to the ER800 as an example:

Wavelength                1535 nm        design property
Pulse Energy              ≥800 µJ        guaranteed minimum
Pulse Width               7 ns           design property of the cavity
Pulse repetition rate     1–10 Hz        adjustable range
Drive pulse width         ≤ 3 ms         guaranteed maximum — do not exceed
Operating temperature     −40 to +65 °C  demonstrated by test

The generated 3D model on each product page can be used to check the mechanical envelope before ordering, and

the datasheet carries the same table in printable form.


The environmental figures

Environmental specifications are a different kind of claim from the optical ones, and it is worth being clear

about how they are established.

Operating temperature — the range over which the published optical performance is maintained. Most models in

this range are specified −40 °C to +65 °C. The high-repetition family (ER10–ER70) is specified −45 °C to +65 °C.

Storage temperature — the range over which the unit may be stored without damage. This is wider than the

operating range, because no optical performance is required while the unit is not running.

Storage range varies across the range, and the variation is real rather than an inconsistency:

Group Models Storage temperature
High-repetition family ER10, ER20, ER40, ER70 −55 °C to +85 °C
MINI-100 MINI-100 −55 °C to +85 °C
Other models ER100 through ER10000 −55 °C to +75 °C

If a requirement calls for storage at +80 °C, that is a question to raise at the specification stage for the

model concerned, rather than something to assume from another model in the range.

Shock — 1500 G for 0.5 ms.

Vibration — 20–2000 Hz at 20 G.

These are demonstrated by test rather than by inspecting each unit. The MINI-100 is additionally stated as

meeting MIL-STD-810G test standards; the other models publish the vibration and shock figures without that

reference, so a programme requiring formal MIL-STD qualification should raise it as a requirement rather than

infer it from a neighbouring model.


Values that are design properties

Some entries in the table cannot meaningfully vary between units, and knowing which ones those are saves

unnecessary concern.

Wavelength. Set by the erbium energy levels in the glass host. Every model in the range is 1535 nm. It is not

tuned per unit and does not drift with drive conditions in any way that matters for a receiver designed for the

band.

Beam quality. TEM00 for the whole range. It follows from the cavity design.

Pulse width. Set by the microchip cavity — the length of the gain medium, the saturable absorber and the

coatings. It is a property of the model, not of the driver. This is why

lengthening the drive pulse does not lengthen the optical pulse.

Polarisation and similar optical properties, where stated, fall into the same category.

These are the entries where comparing two models on the number is meaningful, but where the number is unlikely

to vary between units of the same model.


Values that are nominal, and how to confirm them

Two entries in particular are worth confirming rather than assuming.

Pulse stability — published as 5% or 10% depending on the model. This describes the unit-to-unit and

pulse-to-pulse variation of the energy, and it matters directly to a receiver with a fixed threshold. If the

detection logic is sensitive to amplitude, this is a figure to characterise on the actual unit rather than

design against the datasheet alone.

Beam divergence and raw beam diameter — published so the host optics can be designed. They are nominal

figures, and the divergence is stated as a full angle unless noted otherwise. The

terminology list on the site defines each of these terms as the datasheets use

them.

For anything where the margin is thin, the answer is the same: confirm against the factory test report supplied

with the unit.


Where the numbers affect the design

A short guide to which value to look at for which decision.

The decision The value that decides it
Long range against a diffuse target Pulse energy (guaranteed minimum)
Separating two close returns Pulse width
Update rate, or scan point density Repetition rate
Fitting the envelope Dimensions and weight
What the driver must supply Drive pulse width (maximum), voltage, current
Whether the package survives the environment Operating temperature, shock, vibration
Receiver design Raw beam diameter, beam divergence
Detection threshold margin Pulse stability

If the decision is the last one, note that stability is the figure most likely to need measuring on the actual

unit.


Questions worth asking of any datasheet

Not only these — of any supplier's.

Is this value a minimum, a maximum, or a typical? If the symbol is missing, ask.

At what drive and temperature condition? A pulse energy figure without a stated condition is not comparable

to another.

How was it established — design, test, or calculation? Environmental claims in particular.

What is the test report, and is one supplied with the unit? A factory test report per unit is worth more

than any datasheet, because it describes the part in your hand.

Which values are family-wide rather than per-model? Where models share a mechanical and environmental table,

that is stated on the datasheet itself. The optical parameters are always per model.


How this range is documented

Every model publishes:

  • a specification datasheet with the optical, mechanical and environmental tables
  • a 3D model in glTF binary, for mechanical integration in CAD
  • an outline drawing showing the envelope and mounting features

All of them are linked directly from the Engineering Center, which carries the

full document index. Dimensioned drawings and the controlled STEP source are released on request so that the

correct revision is issued against a specific project.


Related reading

practice

— using the minimum-energy figure in a link budget


Next steps

If a requirement depends on a figure whose status is unclear, Contact / RFQ is the

right route — include the model, the requirement and the value in question, and we will confirm whether it is

guaranteed, typical, or demonstrated by test. The full specification tables are on the

Laser Sources page.