ER2000 is a compact 1535 nm pulsed laser source based on Er:Yb glass microchip technology, designed for sensing, communication and medical systems.
Pulse energy
≥2 mJ
Repetition rate
1~5Hz
Pulse width
12 ns
Dimensions
60×25×13.5mm3
Weight
105 g
KEY FEATURES
✔ 1535 nm Eye-Safe Operation (Class 1)
✔ 2 mJ Pulse Energy
✔ Compact OEM Design
✔ High Pulse Stability
✔ Long Lifetime
Optical Specifications
Wavelength
1535 nm
Pulse Energy
≥2 mJ
Pulse Width
12 ns
Beam Quality
TEM00
Operation
Pulsed
Lifetime
≥10 million shots
Drive pulse width
≤ 4 ms
Pulse repetition rate
1~5Hz
Pulse stability
10%
Raw Beam Diameter
0 .5 mm
Beam divergence angle
≤ 4mrad
Mechanical and Environmental Specifications
Operating temperature
-40 ℃ ~ +65 ℃
Storage temperature
-55 ℃ ~+ 75℃
Dimension (mm)
60×25×13.5mm3
Weight
105 g
Voltage
≤ 5 V
Electric current
80 A
Shock
1500 G, 0.5 ms
Vibration
20~2000 Hz/20 G
Integration Considerations
Review package constraints, electrical requirements and thermal conditions before integration. The driver supply must be matched to the specified voltage and current, and the drive pulse width must remain within the stated limit. For application-specific questions, contact our engineering team with your system requirements.
APPLICATIONS
Environmental and reliability testing, which is what an airborne payload has to survive.On the production line: test and alignment at the bench, where each unit is characterised before it is released.Assembly and alignment. The same bench work sits behind every model in the range.The cleanroom line, where optical assembly is carried out under controlled conditions.
The ER2000 is a 2mJ 1535nm eye-safe erbium glass laser designed as a high-energy core for long-range sensing, free-space and fiber communication links, and precision medical systems, not just laser rangefinders. It uses an Er³⁺/Yb³⁺ co-doped phosphate glass slab with stacked diode-array pumping to deliver millijoule-level pulses while maintaining Class 1 eye-safe operation at 1.54µm.
Optically, the ER2000 provides ≥2mJ pulse energy with a 12ns pulse width and a 1–5Hz repetition rate. Energy stability is specified at about 5% RMS, and the beam is TEM₀₀ with a raw 0.5mm diameter and ≤4mrad full-angle divergence, giving a clean, well-controlled spot that is easy to collimate or couple into external optics, fiber couplers or scanning heads.
The laser head is highly compact (60×25×13.5mm³, 105g) and operates from −40°C to +65°C without TEC, with storage down to −55°C and up to +75°C. An integrated photodiode can be used to monitor each pulse in real time, supporting closed-loop calibration and long-term stability management in demanding instrumentation. The design meets MIL-STD-810G shock and vibration test standards and is rated for a service life of at least 10 million shots.
Beyond classic long-range rangefinders and imaging systems—where high pulse energy and low atmospheric attenuation enable >20km performance on suitable targets—the ER2000 also fits naturally into tactical communication links at 1.5µm, taking advantage of standard telecom windows to reduce loss in field-deployable fiber or free-space optical paths. In the medical field, the strong water absorption at ~1.54µm can be exploited in ophthalmic and dental procedures, where controlled energy deposition in water-rich tissues is required.
With its combination of 2mJ pulse energy, eye-safe wavelength, TEM₀₀ beam quality, compact size and MIL-STD-810G environmental robustness, the ER2000 is a versatile 1535nm source that can sit at the heart of long-range LiDAR channels, precision laser rangefinders, tactical optical communication terminals, medical treatment systems and other infrared sensing platforms that demand both range and reliability.
OUTLINE DIMENSION
Figure 1 Outline Dimensions(mm)
Operating Instructions
Match the laser driver to the ER2000 laser. The laser driver power supply must be properly matched to the laser. The typical load voltage of the ER2000 is < 5 V, with an operating current of 80 A, pulse width < 4 ms, and a repetition rate of 5 Hz. For the exact operating parameters, please refer to the attached factory test report. The laser driver power supply must meet these requirements; otherwise, the laser may fail to operate properly or could be overloaded and permanently damaged. Therefore, before wiring, carefully check the laser specification sheet and confirm that the laser is compatible with the selected driver.
Always disconnect power before wiring. Before making any connections, make sure the power is switched off and completely isolated. During wiring, carefully check the positive and negative terminals of the laser and ensure correct polarity. After the wiring is completed, perform a thorough inspection to confirm that all connections are correct, in order to avoid short circuits, reverse polarity, and other faults. At the same time, make sure all terminals are firmly secured to prevent poor contact due to loose wiring.
Set operating parameters according to the factory test report. After confirming that the wiring is correct, set the corresponding parameters on the driver according to the attached factory test report. Once the parameters are correctly set, turn on the driver; the laser should then operate normally.
Product FAQ
Is this an eye-safe source? Class 1 eye-safe at the specified 1535 nm wavelength.
What is the typical use? Rangefinding, LiDAR, sensing and OEM instrument integration.
Can the package be customised? See OEM / ODM for the customisation scope and review process.
Interactive 3D Model
Drag to rotate, scroll to zoom. The controlled STEP source is available on request for design release.